{"id":683,"date":"2014-09-18T15:59:41","date_gmt":"2014-09-18T13:59:41","guid":{"rendered":"http:\/\/catalinx.ro\/wordpress\/?page_id=683"},"modified":"2015-12-03T22:30:58","modified_gmt":"2015-12-03T20:30:58","slug":"centrala-termica-incalzire-prin-pardoseala-stage-ii-092014","status":"publish","type":"page","link":"https:\/\/catalinx.ro\/wordpress\/?page_id=683","title":{"rendered":"Centrala termica. Incalzire prin pardoseala -Stage II &#8211; 09\/2014"},"content":{"rendered":"<div id=\"fb-root\"><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Circuitele de caldura prin \u0219ape sunt deja finalizate . Ma bantuie in creier metoda de realizare a circuitului teric care sa includa cazanul (~25kw) , un boiler termoelectric de 100-120 litri , \u00a0un #buffer (rezervor de acumulare ) de \u00a0vreo 500 litri \u00a0si , evident , distribuitorul de caldura catre circuitele de pardoseala. \u00a0Distribuitorul am inteles ca-l gasesc cgata facut pe tot cu tot cu cap termostatat ( inca o vana de amestec cred). Va mai trebui sa termostatez eu \u00a0retururile de la circuitele de pardoseala \u00a0, eventual.<\/p>\n<p>Problema majora e integrarea acumulatorului de 500 l in circuit astfel incat \u00a0sistemul sa nu aiba\u00a0<strong>lag\u00a0<\/strong>la incalzirea casei. \u00a0Altfel spus, daca inseriez bufferul simplu , se va incalzi mai intai apa din el , dupa care va \u00a0incalzi restul casei. Dupa \u00a0calculele anterioare , \u00a0500 de litri de apa tin cam 25KWh cu temperatura la varful \u00a0boilerului de 70 grade Celsius. \u00a0 Cum puterea nominala cazanului va fi undevala 25Kw, ar insemna ca \u00a0inserierea acumulatorului ar intarzia incalzirea casei cu \u00a0undeva la o ora. \u00a0 Poate mai putin , daca tinem cont ca amestecul in distribuitor va fi reglat pe la 40-45 de grade , dar oricum sensibil de mult , considerand si faptul ca \u00a0si centrala are ceva lag , pana cand se incalzeste circuitul &#8220;<strong>mic&#8221;\u00a0<\/strong> la 65 de grade pentru a porni recilcularea.<\/p>\n<p>N-as vrea sa dureze timp gen 3-4 ore pana cand se incalzeste casa , iar apoi sa produc bufeuri de caldura nerecuperabila prin faptu ca atunci cand nu se incalzeste bagi lemne in centrala ca inecatul, iar pe urma cand vine valul de caldura \u00a0stai si te uiti ca n-o poti consuma.<\/p>\n<p>Prin urmare vreau un sistem mai inteligent , cu bufferul in derivatie , care sa stocheze doar surplusul de caldura\u00a0si sa introduca intarziere minima in propagarea caldurii. \u00a0Initial analizam posibilitatea \u00a0introducerii unei supape termice , de tipul supapelor de descarcare , dar cu deschidere la temperatura mai mica , care sa introduca acumulatorul in circuit doar cand temperatura apei depaseste 75 de grade. \u00a0Nu prea am vazut astfel de supape \u00a0montabile pe traseu si cu deschideri \u00a0la 75 de grade. Pe de alta parte eu nu-s nici instalator , nici inginer de instalatii.<\/p>\n<p>Oricum , m-am orientat la lucrurile pe care le cunosc. \u00a0Valva de amestec \u00a0cu 3 cai. \u00a0Una similara celei ce se monteaza \u00a0pe circuitul de retur al centralei , pentru a ridica temperatura apei in retur. \u00a0Asa ca am \u00a0montat \u00a0pufferul intr-o derivatie complet pe tur. Doar cu o intrare dinspre centrala si o iesire catre casa. Iesirea pe sus , evident. \u00a0Iesirea \u00a0se intalneste cu turul princpal intr-o vana de-asta de amestec , din care pleaca mai departe din nou o teava de tur.<\/p>\n<p>Planul este urmatorul:<\/p>\n<p>Cand se incalzeste initial apa in tur iar buferul este rece\u00a0 valva de amestec, favorizeaza \u00a0un debit mai mare al apei din \u00a0tur \u00a0fata de apa din derivatie. \u00a0 Daca nu iese apa din buffer , e limpede ca nici nu intra , iar incalzirea continutului sau \u00a0se face doar prin \u00a0conductivitatea termica a apei. Asta in teorie , pentru ca in practica apar curenti \u00a0de convectie (diferenta de densitate) care transporta caldura. Mici , oricum , in comparatie cu viteza de circulatie dictata de pompe. \u00a0Fara curent de fluid \u00a0prin buffer , nu ar trebui sa \u00a0introduca \u00a0cine stie ce disipaatie termica in derivatie , prin urmare si latenta cauzata de incalzirea acumulatorului \u00a0ar trebui sa fie scazuta .<\/p>\n<p>Pentru a acelerea motricitatea \u00a0din punctul \u00a0de iesire al valvei de amestec am prevazut o pompa de recilculare care sa \u00a0directioneze fluxul de apa catre \u00a0distribuitor si sa \u00a0accentueze \u00a0importanta turului centralei prin cererea de debit ( atunci cand \u00a0apa din buffer e rece). Anticipez \u00a0urmatoarele situatii:<\/p>\n<p>T0.<\/p>\n<p>Am pornit focul in centrala . Apa e rece, \u00a0pompa de recirculare retur sta, pompa de circulare tur, s-ar putea sa mearga , daca n-o prevad cu termostat . Ma gandesc&#8230;<\/p>\n<p>T1.<\/p>\n<p>Apa in centrala ajunge la 65 de grade , pompa de recirculare \u00a0din returul centralei porneste . Suplimentul de apa ne amestecata \u00a0cu apa rece din retur este livrat in circuitul de \u00a0incalzire \u00a0al casei . Apa ajunge in \u00a0ce-a de-a doua vana de amestec calda din tur si rece din circuitul \u00a0acumulatorului. \u00a0Pompa trage apa din vana , mai mult calda , dinspre centrala<\/p>\n<p>&nbsp;<\/p>\n<p>T2.<\/p>\n<p>Apa in acumulator se incalzeste si ea la 60 de grade sau mai mult si circula prin circuit in distributie relativ egala cu apa din turul centralei.<\/p>\n<p>&nbsp;<\/p>\n<p>T3. Se termina arderea. \u00a0Temperatura apei din cazan scade sub 65 de grade . Pompa P1 se opreste . Circuitul de incalzire al casei functioneaza independent . Apa din turul centralei se raceste , \u00a0ca urmare a amestecului cu returul circuitului de incalzire din casa. \u00a0Ce-a de a doua vana de amestec trimite inspre pompa 2 in principal apa din rezervorul de acumulare , din partea de sus , la temperatura crescuta.<\/p>\n<p>&nbsp;<\/p>\n<p><del>Asa cum am proiectat acum \u00a0circuitul mai vad o singura problema la care ma gandesc. \u00a0pompa \u00a0P2 functioneaza asincron de P1. \u00a0 \u00a0 Prin urmare , se poate \u00a0( se va intampla) ca pompa 2 sa lucreze si pompa P1 sa stea. Asta atunci cand lemnele vor fi consumate , iar Temperatura in puffer \u00a0si circuitul casei va fi totusi peste 45 de grade si \u00a0apa se va circula in circuitele din pardoseli. In acest caz , supapa de sens proieectata la derivatia returului \u00a0centralei si \u00a0cea de la \u00a0turul boilerului impiedica debitarea apei de catre pompa P2 . Ceea ce inseamna ca \u00a0mai trebuie sa proiectez un bypas intre , de data asta , returul si turul centralei care trebuie , probabil sa se deschida in anumite conditii. Sigur , Il pot lasa liber , dar nu stiu daca vreau sa fac asta.<\/del><\/p>\n<p>Am rezolvat problema prin proiectarea unei legaturi intre tur si retur , cu o supapa de sens dinspre retur inspre tur. Scema din poza de mai sus e deja 2.0<\/p>\n<p><a href=\"http:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-1.jpg\">Aici e schema \u00a0v1.0<\/a><\/p>\n<p><a href=\"http:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-2.jpg\" target=\"_blank\">Schema v.20<\/a><\/p>\n<p><strong>Update:12.12.2014<\/strong><\/p>\n<p>Am omis \u00a0in starea T3 faptul ca circuitul de retur prin centrala se va inchide \u00a0, prin urmare singurul retur inchide un circuit de fluid \u00a0care ar scoate \u00a0bufferul din schema deoarece returul reintra in circuit dupa punctul la care buferul se ailmenteaza. Inainte de acel punct ne mai existand alimentare din retur , nu se poate crea un debit\/ flux de fluid din \u00a0buffer inspre casa.<\/p>\n<p>Exista posibilitatea de amuta returul &#8220;care rezolva functionarea asimetrica P1, P2&#8221; inainte de cei trei robineti R1 , doar ca in felul asta , returul se amesteca cu turul in starea T2. Am optat \u00a0pentru\u00a0mutarea returului \u00a0in alimentarea bufferului.<\/p>\n<p><strong>Versiunea 3.0<\/strong><\/p>\n<p><a href=\"http:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-31.jpg\"><br \/>\n<img loading=\"lazy\" decoding=\"async\" data-attachment-id=\"1148\" data-permalink=\"https:\/\/catalinx.ro\/wordpress\/?attachment_id=1148#main\" data-orig-file=\"https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-31.jpg\" data-orig-size=\"1800,1016\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"Schema-Centrala-termica-3\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-31-1024x577.jpg\" class=\"alignleft size-large wp-image-1148\" src=\"http:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-31-1024x577.jpg\" alt=\"Schema-Centrala-termica-3\" width=\"665\" height=\"374\" srcset=\"https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-31-1024x577.jpg 1024w, https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-31-300x169.jpg 300w, https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-31.jpg 1800w\" sizes=\"auto, (max-width: 665px) 100vw, 665px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Deoarece \u00a0am gasit niste omisiuni \u00a0&#8211; <a href=\"http:\/\/catalinx.ro\/wordpress\/?p=2862\" target=\"_blank\">vezi aici<\/a> &#8211; am ajuns la versiunea 4.0<\/p>\n<p>mai jos :<\/p>\n<p>&nbsp;<\/p>\n<p>Voi re explica procesul termic in zilele ( noptile urmatoare)<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" data-attachment-id=\"2863\" data-permalink=\"https:\/\/catalinx.ro\/wordpress\/?attachment_id=2863#main\" data-orig-file=\"https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2015\/08\/Schema-Centrala-termica-40.jpg\" data-orig-size=\"1800,1016\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Schema-Centrala-termica-40\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2015\/08\/Schema-Centrala-termica-40-1024x578.jpg\" class=\"alignleft wp-image-2863 size-large\" src=\"http:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2015\/08\/Schema-Centrala-termica-40-1024x578.jpg\" alt=\"Schema-Centrala-termica-40\" width=\"700\" height=\"395\" srcset=\"https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2015\/08\/Schema-Centrala-termica-40-1024x578.jpg 1024w, https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2015\/08\/Schema-Centrala-termica-40-300x169.jpg 300w, https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2015\/08\/Schema-Centrala-termica-40-640x361.jpg 640w, https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2015\/08\/Schema-Centrala-termica-40.jpg 1800w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/catalinx.ro\/wordpress\/?p=3153\" target=\"_blank\">Varianta montata , octombrie 2015 &#8211; 4.1<\/a><\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" data-attachment-id=\"3154\" data-permalink=\"https:\/\/catalinx.ro\/wordpress\/?attachment_id=3154#main\" data-orig-file=\"https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-41.jpg\" data-orig-size=\"1800,1016\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Schema-Centrala-termica-41\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-41-1024x578.jpg\" class=\"alignleft size-large wp-image-3154\" src=\"http:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-41-1024x578.jpg\" alt=\"Schema-Centrala-termica-41\" width=\"700\" height=\"395\" srcset=\"https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-41-1024x578.jpg 1024w, https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-41-300x169.jpg 300w, https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-41-640x361.jpg 640w, https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-41.jpg 1800w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/p>\n<p><a href=\"http:\/\/catalinx.ro\/wordpress\/?p=3756\">4.2 aici.<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Circuitele de caldura prin \u0219ape sunt deja finalizate . Ma bantuie in creier metoda de realizare a circuitului teric&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":637,"menu_order":2,"comment_status":"open","ping_status":"open","template":"","meta":{"jetpack_post_was_ever_published":false,"footnotes":""},"class_list":["post-683","page","type-page","status-publish","hentry"],"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/P4Eq23-b1","jetpack-related-posts":[],"_links":{"self":[{"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=\/wp\/v2\/pages\/683","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=683"}],"version-history":[{"count":18,"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=\/wp\/v2\/pages\/683\/revisions"}],"predecessor-version":[{"id":3763,"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=\/wp\/v2\/pages\/683\/revisions\/3763"}],"up":[{"embeddable":true,"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=\/wp\/v2\/pages\/637"}],"wp:attachment":[{"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=683"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}