

{"id":2862,"date":"2015-08-26T08:11:06","date_gmt":"2015-08-26T06:11:06","guid":{"rendered":"http:\/\/catalinx.ro\/wordpress\/?p=2862"},"modified":"2015-08-27T07:06:08","modified_gmt":"2015-08-27T05:06:08","slug":"scurt-despre-termodinamica-si-mecanica-fluidelor","status":"publish","type":"post","link":"https:\/\/catalinx.ro\/wordpress\/?p=2862","title":{"rendered":"Scurt despre termodinamica si mecanica fluidelor"},"content":{"rendered":"<div id=\"fb-root\"><\/div>\n<p>Inca nu m finalizat instalatia termica pentru\u00a0<a href=\"http:\/\/catalinx.ro\/wordpress\/?page_id=633\" target=\"_blank\">Operatiunea Monstrul<\/a>. Voi reveni cu \u00a0o nota vis-avis de renovare si costuri. Deja cred ca buldozerul ar fi fost o versiune la fel de ieftina \/ sau scumpa&#8230;<\/p>\n<p>&nbsp;<\/p>\n<p>Dar altceva vreau sa spun. \u00a0Anume ca aveam schema de mai jos , din pagina <a href=\"http:\/\/catalinx.ro\/wordpress\/?page_id=683\" target=\"_blank\">asta<\/a>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"http:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2014\/09\/Schema-Centrala-termica-31.jpg\" alt=\"\" width=\"1800\" height=\"1016\" \/><\/p>\n<p>Am luat \u00a0centrala (cazanul) , Viadrus D5- \u00a025 kw , un acumulator de 500 de litri ( Vision), un boiler termoelectric de 100 de litri ( am sa v\u0103d eu daca e suficient , dar macar e ieftin) \u00a0. Dupa care am discutat cu echipa, care-mi sunt prieteni ,   despre proiectul meu .<\/p>\n<p>Imi plac oamenii pasiona\u021bi . Gen , proiectul meu \u00a0a stricat somnul unui om :).<\/p>\n<p>Dupa o noapte de \u00a0rumegat am discutat din nou \u00a0\u0219i i am ajuns la urmatoarele concluzii, pe care nu le luasem in calcul initial.<\/p>\n<p>Cum ar fi ca intrarea de apa calda din centrala in \u00a0acumulator o proiectasem in partea de jos si iesirea din partea de sus &#8211; pentru a \u00eenc\u0103lzi omogen bazinul.<\/p>\n<p>\u00cenc\u0103lzirea bazinului , p\u00e2n\u0103 la \u00a0momentul la care \u00a0energia din el e utilizabila , ar dura asa mai mult timp , datorit\u0103 \u00a0inertiei termice si timpului necesar sa se faca echilibrul termic prin curenti de convectie. Nu era o problem\u0103, deoarece  \u00a0valva mea de amestec ar fi adus apa din centrala , prioritar penru incalzirea casei , iar rezervorul ar fi folosit doar pentru acumularea caldurii in exces , iar mai tarziu pentru eliberarea ei.<\/p>\n<p><strong>Doar ca \u00a0e o problema,  c\u0103ci alimentarea cu apa calda pe jos \u00a0obliga la formarea curentilor de convectie care produc o disipatie termica mai mare datorita circulatiei apei calde pe \u00a0o suprafata de contact cu exteriorul m\u0103rit\u0103 , fa\u021b\u0103 de cazul cand circuitul apei calde se face intotdeauna pe sus , iar cel al apei reci pe jos , A\u0219ezarea apei &#8221; in straturi&#8221; e mai economica.<\/strong> Bun argument am primit.<\/p>\n<p>Si pentru ca azinoapte a fost r\u00e2ndul meu sa ma gandesc si sa nu dorm , am scos pompa P2 din circuitul de alimentare al distribuitorului, deoarece acesta are pompa lui care va trage apa \u00a0si am redesenat-o in alimentarea boilerului de apa calda . Va trebui sa fie controlata fie de un termostat de contact \u00a0( sau in imersie ) care sa o porneasca atunci cand temperatura pe tur, in amonte de boiler, va fi de \u00a0peste 60 de grade , fie \u00a0cu un controler diferential si doua \u00a0sonde de temperatura , una pe boiler \u00a0si una inainte de boiler , care sa porneasca pompa \u00a0numai cand diferen\u021ba de temperatura dintre \u00a0turul circuitului si apa din boiler va fi de +10 grade Celsius.<\/p>\n<p>In situatia cu controler \u00a0obtin urmatoarele avantaje:<\/p>\n<p>-Pompa nu circul\u0103 apa decat atunci cand \u00a0in circuit e o temperatura mai mare decat in boiler, deci e o usoara protectie la supraincalzire a centralei. (Posibil ca va trebui sa ii pun un vas de expansiune si boilerului).<\/p>\n<p>&#8211; Apa din boiler va ramane calda, odata incalzita<\/p>\n<p>&#8211; Consum si uzura redusa pe pompa de circulatie<\/p>\n<p>In situatia cu termostat \u00a0simplu \u00a0am\u00a0dezavantajul \u00a0ca atat timp cat temperatura din circuitul tur e mai mare de 60 de grade , sa zicem , apa va merge si prin boiler , chiar daca temperatura din boiler e mai mare ( de la incalzirea anterioara).<\/p>\n<p>Care , s-ar putea sa nu fie de fapt un dezavantaj , ci sa imi permita folosirea boilerului ca acumulator de caldura . Practic, \u00a0daca am un bufeu de temperatura de , sa zicem 85 de grade in toata instalatia si incalzesc , in consecin\u021b\u0103,\u00a0apa din boiler la temperatura asta , iar pe urma \u00a0temperatura din instalatie scade , ca urmare a epuizarii combustibilului , o parte din caldura in exces stocat\u0103 \u00een boiler va fi preluat\u0103 si redata circuitului. Pana cand temperatura \u00a0in circuit (tur)va sc\u0103dea la 60 de grade , moment in care pompa se va opri , \u00eenspre conservarea apei calde stocate in boiler la \u00a0aceasta temperatura. Daca ma gandesc bine ar putea fi si 50 de grade.<\/p>\n<p>Versiunea 4.0.<\/p>\n<p><a href=\"http:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2015\/08\/Schema-Centrala-termica-40.jpg\"><img loading=\"lazy\" decoding=\"async\" data-attachment-id=\"2863\" data-permalink=\"https:\/\/catalinx.ro\/wordpress\/?attachment_id=2863#main\" data-orig-file=\"https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2015\/08\/Schema-Centrala-termica-40.jpg\" data-orig-size=\"1800,1016\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Schema-Centrala-termica-40\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2015\/08\/Schema-Centrala-termica-40-1024x578.jpg\" class=\"alignleft wp-image-2863 size-large\" src=\"http:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2015\/08\/Schema-Centrala-termica-40-1024x578.jpg\" alt=\"Schema-Centrala-termica-40\" width=\"700\" height=\"395\" srcset=\"https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2015\/08\/Schema-Centrala-termica-40-1024x578.jpg 1024w, https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2015\/08\/Schema-Centrala-termica-40-300x169.jpg 300w, https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2015\/08\/Schema-Centrala-termica-40-640x361.jpg 640w, https:\/\/catalinx.ro\/wordpress\/wp-content\/uploads\/2015\/08\/Schema-Centrala-termica-40.jpg 1800w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Inca nu m finalizat instalatia termica pentru\u00a0Operatiunea Monstrul. Voi reveni cu \u00a0o nota vis-avis de renovare si costuri. Deja cred ca buldozerul ar fi fost&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[229],"tags":[554,557,556,553,555],"class_list":["post-2862","post","type-post","status-publish","format-standard","hentry","category-tech","tag-centrala-termica","tag-incalzire-in-pardoseala","tag-montaj-viadrus","tag-operatiunea-monstrul","tag-schema-cu-puffer"],"views":3602,"jetpack_publicize_connections":[],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/p4Eq23-Ka","jetpack-related-posts":[],"_links":{"self":[{"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=\/wp\/v2\/posts\/2862","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2862"}],"version-history":[{"count":2,"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=\/wp\/v2\/posts\/2862\/revisions"}],"predecessor-version":[{"id":2877,"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=\/wp\/v2\/posts\/2862\/revisions\/2877"}],"wp:attachment":[{"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2862"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2862"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/catalinx.ro\/wordpress\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2862"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}